Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Diagnostic Error Codes (Server 330 - x1Y, Pxx)



Error Codes (Server 330 - x1Y, Pxx)

In the following error codes, can be any number or letter.

Diagnostic Error Code/Symptom    FRU/Action
  
01A0h 1. Voltage Regulator
(Application Processor did 2. Processor
not complete in time alloted) 3. Processor Card
  4. System Board
  
01A1h 1. Voltage Regulator
(Failed 586 Instruction test) 2. Processor
  3. Processor Card
  4. System Board
  
01A2h 1. Voltage Regulator
(Failed 486 Instruction test) 2. Processor
  3. System Board
  
01A3h 1. Voltage Regulator
(Failed 386 Instruction test) 2. Processor
  3. System Board
  
01A4h 1. Voltage Regulator
(Failed 386 Register test) 2. Processor
  3. Processor Card
  
01A5h 1. Voltage Regulator
(Failed 386 ALU/Multiply test) 2. Processor
  3. Processor Card
  4. System Board
  
01A6h 1. Voltage Regulator
(Failed 32bit Address test) 2. Processor
  3. Processor Card
  4. System Board
  
01A7h 1. Voltage Regulator
(Unknown error reported 2. Processor
from Application Processor) 3. Processor Card
  4. System Board
  
01A8h 1. Voltage Regulator
(Invalid processor(s) 2. Processor
found/none found to test) 3. Processor Card
  4. System Board
  
01A9h 1. Voltage Regulator
(Application Processor test 2. Processor
error) 3. Processor Card
  4. System Board
  
01AAh 1. Voltage Regulator
(No Application Processor 2. Processor
found) 3. Processor Card
  4. System Board
  
0301h 1. Keyboard
(Keyboard test failed) 2. Keyboard Cable
  3. System Board
  
0303h 1. Keyboard
(Keyboard test failed) 2. Keyboard Cable
  3. System Board
  
0601h 1. Diskette
(Format failed) 2. Diskette drive
  3. System Board
  
0602h 1. Diskette
(Verify failed) 2. Diskette drive
  3. System Board
  
0603h 1. Diskette
(Read failed) 2. Diskette drive
  3. System Board
  
0604h 1. Diskette
(Write failed) 2. Diskette drive
  3. System Board
  
0606h 1. Diskette drive
(General drive failure)
0607h 1. Diskette drive
(Write protect test failure) 2. System Board
  
0608h 1. Diskette drive
(Write protect set on - it 2. System Board
should not be)
0610h 1. System Board
(DMA error on system board)
0613h 1. Diskette
(Media not supported) 2. Diskette Drive
  
0615h 1. Diskette
(Drive was empty) 2. Diskette Drive
  
0617h 1. Rerun Diagnostic
(Program error) 2. Processor Card
  3. System Board
  
0647h 1. Rerun Diagnostic
(Excess drives found with 2. Run Setup
BIOS or in CMOS) 3. System Board
  
0648h 1. Diskette Drive
(Failed resetting controller) 2. System Board
  
0649h 1. Run Setup
(Setup bad. Check system
configuration)
0658h 1. Diskette Drive
(Change Line test failed)
7201h 1. System Board
(Invalid Vector ID or Device ID)
7202h 1. System Board
(Failed Test #1 - I/O Access Test)
7217h 1. System Board
(Unable to Aquire Adapter Base I/O)
7218h 1. System Board
(Unable to Aquire Adapter IRQ)
7219h 1. System Board
(Failed Ethernet Data Transceiver
test. See 'Error Code 7219')
AA05h 1. Processor Card
(PROBLEM DETERMINING DIMM
PHYSICAL ADDRESSES)
AA06h 1. Processor Card
(PCI BIOS call failed) 2. System Board
  
AA07h 1. DIMMs 1, 2, 3
(DATA AREA FAILS TEST) 2. Processor Card
  
AA08h 1. DIMMs 1, 2, 3
(ECC un-correctable memory 2. Processor Card
error detected)
AA09h 1. DIMMs 1, 2, 3
(ECC correctable memory 2. Processor Card
error detected)
AA0Ah 1. DIMMs 1, 2, 3
(Both single and multiple bit 2. Processor Card
errors detected)
AA0Bh 1. Processor Card
(PCI BIOS call failed! 2. System Board
CONFIG ADDR NOT ON BOUNDARY)
AA0Ch 1. DIMMs 1, 2, 3
(UnExpected NMI occured!) 2. Processor Card
  3. System Board
  
AA0Dh 1. Processor Card
(ECC forced single bit error 2. Processor Card
 
was NOT detected)
AA0Eh 1. Processor Card
(The forced ECC-single bit error
was NOT detected and an
UNEXPECTED Un-Correctable error
occured!)
AA0Fh 1. Processor Card
(The forced ECC-single bit error
was detected and an UNEXPECTED
Un-Correctable error occured!)
AA10h 1. Processor Card
(The data was NOT corrected)
AA11h 1. Processor Card
(PCI BIOS call failed!) 2. System Board
  
AA12h 1. Processor Card
(EXPECTED NMI did NOT occur!) 2. System Board
  
AA13h 1. Processor Card
(Forced Un-Correctable error
was NOT detected!)
AA14h 1. Processor Card
(The Forced Un-Correctable error
was NOT detected and an UNEXPECTED
ECC Correctable error occurred!)
AA15h 1. Processor Card
(The ECC forced un-correctable
error detected OK but an UNEXPECTED
ECC Correctable error occurred!)
AA16h 1. DIMMs 1, 2, 3
(ECC un-correctable 2. Processor Card
memory error detected!)
AA17h 1. DIMMs 1, 2, 3
(ECC correctable 2. Processor Card
memory error detected!)
AA18h 1. DIMMs 1, 2, 3
(Both single and multiple 2. Processor Card
bit errors)
AA19h 1. Processor Card
(PCI BIOS is NOT supported!) 2. System Board
  
AA1Ah 1. Processor Card
(PCI BIOS did NOT find 2. System Board
Memory Controller)
AA1Bh 1. Processor Card
(ERROR READING Memory
Controller Config Register)
AA1Ch 1. Processor Card
(UNKNOWN Memory
Controller Release level)
AA1Dh 1. DIMM
(DIMM IS SMALLER THAN 2. Processor Card
SYSTEM SUPPORTS)
AA1Eh 1. DIMM
(DIMM IS LARGER THAN 2. Processor Card
SYSTEM SUPPORTS)
AA23h 1. Processor Card
(Memory Controller DRAM row
boundary Register data error)
AA24h 1. DIMMs 1, 2, 3
(MTRRs exceed program maximum!) 2. Processor Card
  
AA25h 1. DIMMs 1, 2, 3
(MTRRs NOT supported!) 2. Processor Card
  
AA26h 1. Processor
(CPUID NOT recognized!) 2. Processor Card
  
AA27h 1. DIMMs 1, 2, 3
(Invalid MTRR service request!) 2. Processor Card
  
AA29h 1. DIMMs 1, 2, 3
(MEMORY CONTROLLER HAS LOGGED 2. Processor Card
AN ERROR!)
AA2Ah 1. Specified DIMM
(DIMM in connector Jx 2. Processor Card
FAILS FAST ACCESS SPEED TEST
(PATTERN 0)!)
AA2Bh 1. Specified DIMM
(DIMM in connector Jx 2. Processor Card
FAILS FAST ACCESS SPEED TEST
(PATTERN 1)!)
AA2Ch 1. DIMMs 1, 2, 3
(MEMORY ADDRESS TEST FAILED!) 2. Processor Card
  
AA2Dh 1. Specified DIMM
(DIMM in connector Jx 2. Processor Card
IS STUCK-AT-0)
AA2Eh 1. Specified DIMM
(DIMM in connector Jx 2. Processor Card
IS STUCK-AT-1)
AA2Fh 1. Specified DIMM
(DIMM in connector Jx 2. Processor Card
FAILS ASCII R/W TEST!)
AA30h 1. Specified DIMM
(DIMM in connector Jx 2. Processor Card
PROBLEM DETERMINING
DIMM 16KB ALIGNMENT!)
AA31h 1. Specified DIMM
(DIMM in connector Jx NMI 2. Processor Card
HANDLER FAILED TO INSTALL OK!)
0901h 0902h 0904h 1. System Board
0906h 0908h 090Ah
(Parallel Test Failed)
8601h 1. Pointing Device
(Bad Pointing Device)
8602h 1. Pointing Device
(User detected pointing device
error)
8603h 1. Attach Mouse
(No pointing device was found) 2. Rerun Diagnostic
  
11xxh 1. System Board
(Serial Test Failed)
0104h 0105h 0106h 1. System Board
0109h
(Planar Test Failed)
0501h 1. System Board
(Video register test error)
0503h 1. System Board
(Video frequency test error)
0506h 1. System Board
(Video get VESA mode error)
0511h 1. System Board
(Video get VGA mode error)
0513h 1. System Board
(Video frequency test
time out error)
0521h 1. System Board
(Video DAC test error)
0522h 1. System Board
(Video attribute test error)
0523h 1. System Board
(Video visual test error)
0524h 1. Video Monitor
(Video monitor test error) 2. System Board
  
0530h 1. System Board
(Video Memory module #1 error)
0531h 1. System Board
(Video Memory module #2 error)
0532h 1. Video Memory Module
(Video Memory module #3 error) 2. System Board
  
0533h 1. Video Memory Module
(Video Memory module #4 error) 2. System Board
  
0540h 1. Rerun Diagnostic
(Video Test error) 2. System Board


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.