Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Error Messages (TP 570 - 2644)



Error Messages
Symptom / error    FRU / action in sequence
  
Device address conflict 1. Load Setup Defaults in IBM BIOS Setup Utility
  2. Backup battery
  3. System board
  
Allocation error for device 1. Load Setup Defaults in IBM BIOS Setup Utility
  2. Backup battery
  3. System board
  
Failing Bits: nnnn 1. DIMM
  2. System board
  
Invalid System Configuration Data 1. DIMM
  2. System board
  
I/O Device IRQ Conflict 1. Load Setup Defaults in IBM BIOS Setup Utility
  2. Backup battery
  3. System board
  
Operating System not found 1. Enter IBM BIOS Setup Utility and see whether
      the hard disk drive and diskette drive are
      properly identified
  2. Diskette drive
  3. Hard disk drive
  4. System board


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.