Symptom / error | FRU / action in sequence |
---|---|
0200 | 1. Reseat the hard disk drive |
Fixed disk failure | 2. Load Setup Defaults in IBM BIOS Setup Utility |
3. Hard disk drive | |
4. System board | |
0210, 0211 | |
Stuck key Keyboard error | 1. Run the keyboard test in the interactive tests and auxiliary |
input device | |
0212 | 1. Run the keyboard test in the interactive tests and auxiliary |
Keyboard controller failure | input device |
0213 | 1. Unlock external keyboard |
Keyboard is locked - | |
Unlock key switch | |
0220 | 1. Load Setup Defaults in IBM BIOS Setup Utility |
Monitor type does not match | |
CMOS - run setup | |
0230 | 1. System board |
Shadow RAM failure at | |
offset nnnn | |
0231 | 1. DIMM |
System RAM failure at | 2. System board |
offset nnnn | |
0250 | 1. Replace the backup battery and run IBM BIOS Setup Utility to |
System battery is dead - | reset the time and date |
Replace and run setup | |
0251 | 1. Replace the backup battery and run IBM BIOS Setup Utility to |
System CMOS checksum bad - | reset the time and date |
Default configuration used | |
0260 | 1. Replace the backup battery and run IBM BIOS Setup Utility to |
System timer error | reset the time and date |
2. System board | |
0270 | 1. Replace the backup battery and run IBM BIOS Setup Utility to |
Real time clock error | reset the time and date |
2. System board | |
0280 | 1. Load Setup Defaults in IBM BIOS Setup Utility |
Boot incomplete error - | 2. DIMM |
Default configuration used | 3. System board |
0281 | 1. Load Setup Defaults in IBM BIOS Setup Utility |
Memory size recognized by | 2. DIMM |
POST is different from that | 3. System board |
recognized by CMOS | |
02B0 | 1. Check that the drive is defined with the proper diskette type |
Diskette drive error | in IBM BIOS Setup Utility |
2. Run the diskette diagnostics test | |
02D0 | 1. System board |
System cache error - | |
Cache is disabled | |
02F0 | 1. System board |
CPU ID | |
02F5 | 1. DIMM |
DIMM test failure | 2. System board |
02F6 | 1. DIMM |
Software NMI failure | 2. System board |
02F7 | 1. DIMM |
Fail - Safe timer NMI failure | 2. System board |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.