IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Power Systems Checkout (TP 570 - 2644)
Power Systems Checkout
To verify the symptom of a problem, do the following:
- Power off the computer.
- Remove the battery pack.
- Connect the AC Adapter.
- Check that power is supplied when you power on the computer.
- Power off the computer.
- Disconnect the AC Adapter and install the charged battery pack.
- Check that power is supplied by the battery pack when you power on the computer.