Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric Error Codes and Messages



  Numeric POST Error Codes and Messages
Error Code/Message    FRU/Action in Sequence
006 1. Ensure the equipment (diskette drive, hard disk drive, keyboard,
Equipment Configuration Error     external mouse, etc.) is connected properly and is correctly set
      in the BIOS Utility.
  2. Hard disk connection board
  3. Hard disk drive
  4. Planar board
  
010 1. Go to 'Memory Check'.
Memory Error at 2. DIMM
 
MMMM:SSSS:OOOOh(R:xxxxh, W:xxxxh) 3. Planar board
  
040 1. Go to 'Diskette Drive Check'.
Diskette Drive Controller Error 2. Ensure the diskette drive configuration setting in BIOS Utility
      is correct.
  3. Diskette drive cable
  4. Diskette drive
  5. Planar board
  
047 1. Ensure the diskette drive is not set to "Disabled' in the
Diskette Drive(s) Disabled     "System Security" menu of the BIOS Utility.
  2. Diskette drive cable
  3. Diskette drive
  
050 1. Ensure the hard disk drive is set to "Auto' in the
IDE Drive 0 Error     "Basic System Settings" menu of the BIOS Utility.
  2. Hard disk connection board
  3. Hard disk drive
  4. Planar board
  
054 1. Ensure the hard disk drive is not set to "None' in the
IDE Drive(s) Disabled     "Basic System Settings" menu of the BIOS Utility.
  2. Hard disk drive cable
  3. Hard disk drive
  
056 1. Ensure the hard disk drive is set to "Auto' in the
IDE Drive 0 Auto     "Basic System Settings" menu of the BIOS Utility.
Detection Failed 2. Hard disk connection board
  3. Hard disk drive
  4. Planar board
  
070 1. Reset time in the "Basic System Settings" menu of the BIOS Utility.
Real Time Clock Error 2. Backup battery (RTC battery)
  3. Planar board
  
071 1. Enter BIOS Utility and execute "Load Setup Default Settings".
CMOS Battery Bad 2. Backup battery (RTC battery)
  3. Planar board
  
072 1. Enter BIOS Utility and execute "Load Setup Default Settings",
CMOS Checksum Error     then reboot the system.
  2. Backup battery (RTC battery)
  3. Planar board


Numeric System Operation (Runtime) Error Codes and Messages
Error Code/Message    FRU/Action in Sequence
103 1. Enter BIOS Utility and execute "Load Setup Default Settings",
Press <Esc> to turn off     then reboot the system.
NMI or other key to reboot 2. Remove the nonfactory-installed adapter card and reboot the system.


More INFORMATION / HELP is available at the  IBM-HelpCenter