Error Code/Message | FRU/Action in Sequence |
---|---|
006 | 1. Ensure the equipment (diskette drive, hard disk drive, keyboard, |
Equipment Configuration Error | external mouse, etc.) is connected properly and is correctly set |
in the BIOS Utility. | |
2. Hard disk connection board | |
3. Hard disk drive | |
4. Planar board | |
010 | 1. Go to 'Memory Check'. |
Memory Error at | 2. DIMM |
MMMM:SSSS:OOOOh(R:xxxxh, W:xxxxh) | 3. Planar board |
040 | 1. Go to 'Diskette Drive Check'. |
Diskette Drive Controller Error | 2. Ensure the diskette drive configuration setting in BIOS Utility |
is correct. | |
3. Diskette drive cable | |
4. Diskette drive | |
5. Planar board | |
047 | 1. Ensure the diskette drive is not set to "Disabled' in the |
Diskette Drive(s) Disabled | "System Security" menu of the BIOS Utility. |
2. Diskette drive cable | |
3. Diskette drive | |
050 | 1. Ensure the hard disk drive is set to "Auto' in the |
IDE Drive 0 Error | "Basic System Settings" menu of the BIOS Utility. |
2. Hard disk connection board | |
3. Hard disk drive | |
4. Planar board | |
054 | 1. Ensure the hard disk drive is not set to "None' in the |
IDE Drive(s) Disabled | "Basic System Settings" menu of the BIOS Utility. |
2. Hard disk drive cable | |
3. Hard disk drive | |
056 | 1. Ensure the hard disk drive is set to "Auto' in the |
IDE Drive 0 Auto | "Basic System Settings" menu of the BIOS Utility. |
Detection Failed | 2. Hard disk connection board |
3. Hard disk drive | |
4. Planar board | |
070 | 1. Reset time in the "Basic System Settings" menu of the BIOS Utility. |
Real Time Clock Error | 2. Backup battery (RTC battery) |
3. Planar board | |
071 | 1. Enter BIOS Utility and execute "Load Setup Default Settings". |
CMOS Battery Bad | 2. Backup battery (RTC battery) |
3. Planar board | |
072 | 1. Enter BIOS Utility and execute "Load Setup Default Settings", |
CMOS Checksum Error | then reboot the system. |
2. Backup battery (RTC battery) | |
3. Planar board |
Numeric System Operation (Runtime) Error Codes and Messages
Error Code/Message | FRU/Action in Sequence |
---|---|
103 | 1. Enter BIOS Utility and execute "Load Setup Default Settings", |
Press <Esc> to turn off | then reboot the system. |
NMI or other key to reboot | 2. Remove the nonfactory-installed adapter card and reboot the system. |