IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Checking the Installed Devices List (TP 560Z - 2640)
Checking the Installed Devices List
If a device is installed but the icon appears in a gray shade
rather than a dark shade on the basic diagnostics test
menu, the device is defective. Reseat the device
connectors. If the symptom remains, replace the device or
the system board.
If a device that is not installed appears in a dark shade (for example,
FDD-2 appears in a dark shade when no second FDD is installed), do the following:
- Replace the first device in the configuration, such as an FDD-1.
- If the problem persists, replace the system board.
The Parallel, and Serial icons are always displayed in a
dark shade, because the icons represent subsystems of
the system board and not the attachment of the devices.
The FDD-1 icon represents the first drive in the system
configuration for each type of device. For Model 560Z,
FDD-1 represents an external diskette drive attached
through the external diskette drive connector. Similarly,
the FDD-2 icon represents the second drive, usually
attached through a port replicator.