Undetermined Problems (TP 560Z - 2640)
Undetermined Problems
You are here because the diagnostic tests did not identify
which adapter or device failed, installed devices are
incorrect, a short circuit is suspected, or the system is
inoperative. Follow these procedures to isolate the failing
FRU (do not isolate nondefective FRUs).
Verify that all attached devices are supported by the computer.
Verify that the power supply being used at the time of the
failure is operating correctly. (See 'Power Systems Checkout'):
- Power off the computer.
- Visually check them for damage. If any problems are found, replace the FRU.
- Remove or disconnect all of the following devices:
- Non-IBM devices.
- Devices attached to the port replicator.
- Printer, mouse, and other external devices.
- Battery pack.
- Hard disk drive.
- External diskette drive.
- DIMM card.
- PC cards.
- Power on the computer.
- Determine if the problem has changed.
- If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
- If the problem remains, replace the following FRUs one at a time. Do not replace a nondefective FRU.
- System board.
- LCD assembly.
- CPU mini-cartridge.