IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Memory Checkout (TP 380XD, 385XD, 380Z - 2635)
Memory Checkout
DIMMs are available for increasing memory capacity.
DIMM |
Displayed Value |
No DIMM installed |
32192 KB |
8 MB (380XD, 385XD) |
40384 KB |
16 MB |
48576 KB |
32 MB |
64960 KB |
64 MB |
97728 KB |
Memory errors might cause error messages to appear on the screen, or may hang the operating system.
Take the following procedure to isolate memory problems:
- Power off the computer and remove any installed DIMM from the slot.
- Press and hold the F1 key, then power on the computer.
Hold the F1 key down until the Easy-Setup menu appears.
- Select Test and press Enter
- Select Memory and press Enter to run the memory
test on base memory. If an error appears, replace the system board.
- Power off the computer and reinstall the DIMM, then power on the computer.
Verify the memory size, then test the memory. If an error appears, replace
the DIMM.
NOTE: Make sure that the DIMM is fully installed into the connector.
A loose connection can cause an error.
If a memory problem occur intermittently, use the loop option to repeat the test.
When the test detects an error, an error log is printed on the printer connected to the parallel port.
See 'Displaying the Error Log' for more information.
Back to 
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.