 |
IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Checking the Installed Devices List (TP 600/600E - 2645)
Checking the Installed Devices List
If a device is installed but the icon appears in a gray shade rather
than a dark shade on the basic diagnostics menu,
the device is defective. Reseat the device connectors.
If the symptom remains, replace the device or the system board.
If needed, adjust the contrast control to clearly
distinguish the shades of the icon.
If a device that is
not installed appears in a dark shade (for example, FDD-2
appears in a dark shade when NO
second FDD is installed), do the following:
- Replace the first
device in the configuration, such as an FDD-1.
- If the problem remains, replace the system board.
The Parallel, and Serial icons
are always displayed in a dark shade because the
icons represent subsystems of the system board and
not the actual attachment of the devices.
The FDD-1 icon represents a device in the UltraslimBay.
The FDD-2 icon represents another device such as:
- An external diskette drive attached to the computer.
- An external diskette drive attached to a port replicator.
- A diskette drive in a docking station.
Back to 
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.