Checking the Installed Devices List (765D-9546 765L-9547)
Checking the Installed Devices List
If a device is installed but the icon appears in a gray shade rather
than a dark shade on the basic diagnostics screen,
the device is defective. Reseat the device connectors.
If the symptom remains, replace the device or the system board.
If needed, adjust the contrast control to clearly
distinguish the shades of the icon.
If a device that is
not installed appears in a dark shade (for example, FDD-2
appears in a dark shade when NO
second FDD is installed), do the following:
- Replace the first
device in the configuration, such as the FDD-1.
- If the problem remains, replace the system board.
The Parallel, and Serial icons
are always displayed in a dark shade because the
icons represent subsystems of the system board and
not the actual attachment of the devices.
The FDD-1
icon represents the first drive in the system configuration.
The FDD-2 icon represents another device, such as:
- An external diskette drive attached to the computer
- An external diskette drive attached to a port replicator
- A diskette drive in a docking station