Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

PCMCIA-Related Symptoms (765D-9546 765L-9547)



PCMCIA-Related Symptoms

Symptom / Error    FRU / Action in Sequence
  
PC Card does not work in either 1. Reseat the PCMCIA flexible cable before
upper slot or the lower slot.     replacing the PCMCIA slot
Diagnostic error code:     (See 'PCMCIA Slot Assembly')
DEV 080 2. PCMCIA slot assembly.
ERR 33
FRU 7210
CardBus slot pin is damaged    PCMCIA slot assembly
  
CardBus does not work. 1. Reseat the PC Card
  2. Check the PC Card is enabled in the ThinkPad
      Configuration program.
  3. Reseat the PCMCIA flexible cable
      (See 'PCMCIA Slot Assembly')


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.