FRU Code | FRU/Action |
---|---|
10 | System Board |
11 | CPU Card |
15 | ESS card |
16 | DSP card |
17 | Front IR unit |
18 | Rear IR unit |
20 | Memory (See 'Memory Checkout'.) |
30 | Reserved |
32 | External Keyboard |
33 | External Mouse |
40 | LCD Assembly |
42 | Video card |
45 | External CRT |
50 | 1. Reseat the Diskette Drive (FDD-1) 2. Reseat the external FDD cable on the video card 3. Diskette Drive (FDD-1) |
51 | 1. Reseat the Diskette Drive (FDD-2) 2. Reseat the external FDD cable on the video card 3. Diskette Drive (FDD-2) |
60 | 1. Reseat the Hard Disk Drive (HDD-1) 2. Hard Disk Drive (HDD-1) |
61 | 1. Reseat the Hard Disk Drive (HDD-3) 2. Hard Disk Drive (HDD-3) |
62 | 1. Reseat the Hard Disk Drive in UltraBay (HDD-2) 2. Hard Disk Drive in UltraBay (HDD-2) |
63 | 1. Reseat the Hard Disk Drive (HDD-4) 2. Hard Disk Drive (HDD-4) |
70 | PCMCIA-2 (replicator) |
71 | PCMCIA (UltraBay) |
72 | 1. Reseat the PCMCIA flexible cable 2. PCMCIA Slot Assembly |
90 | CD-ROM Drive |
91 | External CD-ROM Drive |
NOTE: The device ID and error codes are used to
indicate the detailed portion of the FRU that caused the error.
If replacing a FRU does not correct the problem see the device ID error code from the
previous failure. If they have changed, the cause might be because the new
FRU is defective or that the FRU was incorrectly installed.
If the problem remains after replacement of the FRUs,
go to 'Undetermined Problems'.
Please see the LEGAL - Trademark notice.