Symptom or Error | FRUs of the SelectaDock |
---|---|
Sequence of Actions | |
10X, 11X | 1. Adapter in slot (if used) |
101: Interrupt failure. | 2. Riser card |
102: Timer failure. | 3. Main card |
103: Timer interrupt failure. | |
104: Protected mode failure. | |
105: Last 8042 command not accepted. | |
107: NMI test failure. | |
108: Timer bus test failure. | |
109: Low meg-chip select test. | |
195 | Do the following steps: |
(The computer was docked to the | a. Power-off and undock the system. |
SelectaDock Docking system while | b. Power-on and shut down the system. |
in hibernation mode.) | c. Power-off and dock the system. |
1XX | 1. See the Hardware Maintenance Manual of the computer. |
If the problem remains, go to Undetermined Problems | |
2XX | 1. See the Hardware Maintenance Manual of the computer. |
201: Memory data error. | 2. Main card |
202: Memory line error 00-15. | |
203: Memory line error 16-23. | |
205: Memory test failure on on-board memory. | |
221: ROM to RAM remap error. | |
3XX | 1. See External Keyboard |
6XX | 1. Before changing any devices, run the diagnostic test. |
(See the How to Run the Diagnostics) | |
2. FDD external attachment kit | |
3. Diskette drive assembly | |
4. Riser card | |
11XX, 12XX | 1. Serial devices |
2. Communication cable | |
3. Riser card | |
17XX | 1. Hard disk drive (2.5-inch ThinkPad hard disk drive) |
2. Main card | |
24XX | 1. Main card |
2. Riser card | |
860X | 1. Mouse |
2. External keyboard | |
3. Riser card | |
I9990301, I9990302 | 1. See the Hardware Maintenance Manual for the computer. |
I9990305 | |
Not shown above | 1. See the Hardware Maintenance Manual for the computer. |
2. See Undetermined Problems. |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.