Symptom/Error | FRU/Action |
---|---|
The system will not suspend or resume | 1. Go to 'Suspend Mode' |
by opening or closing the keyboard. | and check that the computer |
can enter Suspend Mode | |
2. Go to Easy-Setup screen and press Fn+4. | |
If the computer enters suspend mode | |
suspect that the application program | |
is defective. | |
3. DC/DC Card | |
4. Interposer Card | |
5. System Board | |
The system will not suspend | 1. Go to 'Suspend Mode' |
or resume by opening or | and check that the computer |
closing the LCD. | can enter suspend mode. |
2. Go to Easy-Setup screen and press Fn+4. | |
If the computer enter suspend mode | |
suspect that the application program | |
is defective. | |
3. Interposer Card | |
4. DC/DC Card | |
5. System Board | |
Battery Fuel-Gauge does | 1. Go to 'Checking the Battery Pack' |
not go higher than 90%. | and see the note. |
Audio problems. | 1. Run the Audio Test. |
2. Audio Card | |
Memory count (size) appears | 1. Go to 'Memory Checkout' |
differently from actual size. | |
System configuration does | 1. Go to 'Checking the Installed Devices List' |
not match the installed devices. | |
System hangs intermittently. | 1. Go to 'Intermittent Problems' |
Please see the LEGAL - Trademark notice.