| Symptom/Error | FRU/Action |
|---|---|
| Indicator incorrectly remains on | 1. Reseat the inverter card. |
| or off, but system runs correctly. | 2. Inverter Card. |
| 3. Top System Board. | |
| Battery status indicator blinks | 1. Check that a fully charged battery is |
| green and beeps three times | installed. |
| at power-on or Resume. | 2. Battery Pack |
| 3. Reseat Top and Bottom System Boards together. | |
| 4. Top System Board. | |
| 5. Bottom System Board. | |
| Battery status indicator blinks | 1. Check the card-to-card connection. |
| green at power-on. | Reseat Top and Bottom System Boards together. |
| 2. Top System Board. | |
| 3. Bottom System Board. | |
| Battery status indicator does | 1. This is normal operation if charging continues. |
| not turn on when battery fuel | Leave the computer charging, and then |
| gauge is over 90% but less | recheck the battery fuel gauge a short |
| than 100% | time later to see whether the charge has |
| increased. |