Memory Checkout
Memory Checkout
See the following table for the available memory
size of each card.
| IC DRAM |
Memory size |
| 0 MB |
3712 KB |
| 2 MB |
5760 KB |
| 4 MB |
7808 KB |
| 8 MB |
11904 KB |
Memory errors might stop system operations, show error messages on
the screen, or hang the system.
Use the following procedure to isolate memory problems.
NOTE: Make sure that the memory card is fully installed
into the connector.
Loose connections can cause errors.
- Power-off the computer and
remove the IC DRAM card from its slot (if installed).
- Press and hold the F1 key; then power-on the computer.
Hold the F1 key down until the Easy-Setup screen appears.
- Select Test and press enter.
- Select Memory and press enter to
run the memory test on base memory. If an error appears, replace the
system board.
- Power-off the computer and reinstall the IC DRAM card,
then power-on the computer.
Verify the memory size, then test the memory.
If an error appears, replace the IC DRAM card.
If memory problems occur intermittently,
use the loop option to repeat the test.
When the test detects an error,
an error log is printed on the
printer connected to the parallel port.
See 'Error Log' for more information.