Jumper Settings for TX98-3D/TX98
TX98-3D/TX98 provides two modes for Jumper Settings: (1) Auto Jumper
Mode; (2) Manual mode.
Auto Jumper Mode
An advanced
technology eliminates the necessity for the user to be bored by jumper settings
on the mainboard. It is capable of detecting the CPU brand, and setting the
appropriate CPU core voltage and speed according to instructions from the user
through CMOS setup menu.
To enable Auto Jumper Mode, short JP16 to
position (1-2).
Manual Mode
To enable Manual Mode,
short JP16 to position (2-3) and follow the jumper table below for necessary
jumper settings for CPU installed.
FOR INTEL PENTIUM / PENTIUM
WITH MMX TECHNOLOGY CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ3 | FQ2 | FQ1 | Frequency Ratio | BF2 | BF1 | BF0 |
100 | 66 | [1-2] | [1-2] | [1-2] | 1.5x | [1-2] | [1-2] | [1-2] |
120 | 60 | [1-2] | [1-2] | [2-3] | 2.0x | [1-2] | [1-2] | [2-3] |
133 | 66 | [1-2] | [1-2] | [1-2] | 2.0x | [1-2] | [1-2] | [2-3] |
150 | 60 | [1-2] | [1-2] | [2-3] | 2.5x | [1-2] | [2-3] | [2-3] |
166 | 66 | [1-2] | [1-2] | [1-2] | 2.5x | [1-2] | [2-3] | [2-3] |
200 | 66 | [1-2] | [1-2] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
233 | 66 | [1-2] | [1-2] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
FOR CYRIX/IBM 6x86/6x86MX/MII CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ3 | FQ2 | FQ1 | Frequency Ratio | BF2 | BF1 | BF0 |
P150+ | 60 | [1-2] | [1-2] | [2-3] | 2.0x | [1-2] | [1-2] | [2-3] |
P166+ | 66 | [1-2] | [1-2] | [1-2] | 2.0x | [1-2] | [1-2] | [2-3] |
PR200 | 75 | [1-2] | [2-3] | [1-2] | 2.0x | [1-2] | [1-2] | [2-3] |
PR233 | 66 | [1-2] | [1-2] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
PR233 | 75 | [1-2] | [2-3] | [1-2] | 2.5x | [1-2] | [2-3] | [2-3] |
PR266 | 66 | [1-2] | [1-2] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
PR266 | 83 | [2-3] | [1-2] | [2-3] | 2.5x | [1-2] | [2-3] | [2-3] |
PR300 | 66 | [1-2] | [1-2] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
PR300 | 75 | [1-2] | [2-3] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
PR333 | 66 | [1-2] | [1-2] | [1-2] | 4.0x | [2-3] | [1-2] | [2-3] |
PR333 | 75 | [1-2] | [2-3] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
PR333 | 83 | [2-3] | [1-2] | [2-3] | 3.0x | [1-2] | [2-3] | [1-2] |
FOR AMD-K5/K6/K6-2 CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ3 | FQ2 | FQ1 | Frequency Ratio | BF2 | BF1 | BF0 |
PR100 | 66 | [1-2] | [1-2] | [1-2] | 1.5x | [1-2] | [1-2] | [1-2] |
166 | 66 | [1-2] | [1-2] | [1-2] | 2.5x | [1-2] | [2-3] | [2-3] |
200 | 66 | [1-2] | [1-2] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
233 | 66 | [1-2] | [1-2] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
266 | 66 | [1-2] | [1-2] | [1-2] | 4.0x | [2-3] | [1-2] | [2-3] |
300 | 66 | [1-2] | [1-2] | [1-2] | 4.5x | [2-3] | [2-3] | [2-3] |
333 | 66 | [1-2] | [1-2] | [1-2] | 5.0x | [2-3] | [2-3] | [1-2] |
FOR IDT-C6 CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ3 | FQ2 | FQ1 | Frequency Ratio | BF2 | BF1 | BF0 |
150 | 50 | [2-3] | [2-3] | [2-3] | 3.0x | [1-2] | [2-3] | [1-2] |
150 | 75 | [1-2] | [2-3] | [1-2] | 2.0x | [1-2] | [1-2] | [2-3] |
180 | 60 | [1-2] | [1-2] | [2-3] | 3.0x | [1-2] | [2-3] | [1-2] |
200 | 66 | [1-2] | [1-2] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
255 | 75 | [1-2] | [2-3] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
CPU Voltage Selection
CPU Type | Voltage Requirements |
---|---|
Intel Pentium Cyrix/IBM M1 6x86 AMD K5 IDT-C6 |
3.4V(STD) / 3.5V(VRE) |
Intel Pentium with MMX Cyrix/IBM M1 6x86L |
2.8V |
Cryix/IBM 6x86MX AMD-K6-166, 200 |
2.9V |
AMD-K6-233 | 3.2V |
AMD-K6-266, 300, K6-2 | 2.2V |
CPU Core Voltage Table
Vcore | VID4 | VID3 | VID2 | VID1 | VID0 |
2.2V | [1-2] | [1-2] | [1-2] | [2-3] | [1-2] |
2.8V | [1-2] | [2-3] | [1-2] | [1-2] | [1-2] |
2.9V | [1-2] | [2-3] | [1-2] | [1-2] | [2-3] |
3.2V | [1-2] | [2-3] | [2-3] | [1-2] | [1-2] |
3.3V | [1-2] | [2-3] | [2-3] | [1-2] | [2-3] |
3.4V | [1-2] | [2-3] | [2-3] | [2-3] | [1-2] |
3.5V | [1-2] | [2-3] | [2-3] | [2-3] | [2-3] |
Special Function
Keys
Press the key "F" during power on to clear the CMOS
Press the
key "J" during power on to re-detect
the CPU
Copyright(c) 1998 Zida Technologies Limited. All Rights
Reserved.
Last Updated on 17
July 1998
Legal Notice