P6L40-A4E Mainboard BIOS

-V1.00 ( 1998/2/5 ) ===> Status : Released

* TRM-P6L40A4E-V1.00
* Initial release
* All H/W monitorings ( CPU thermal/Fan/System 5V ) are default to be disabled
* Using faster DRAM timing since no buffer delay required
* Added power state save feature for Power Failure
  This feature must be used in combination of JPX1
  When JPX1 opened  ==> this feature is disabled and this option must be set to
			ON for proper operation
  When JPX1 shorted ==> this feature is enabled and all option can be set and
			function is as the following table
  ( This feature is disabled by manufacturing, i.e. JPX1 opened and option
    set to ON. For user need this feature, short JPX1 and set this option
    accordingly ).

			    System state when | System state when
			    power failure     | power recovered
			    ------------------+------------------
  1. Former State --		ON	      | 	ON
				OFF	      | 	OFF
			    ------------------+------------------
  2. Off			ON	      | 	OFF
				OFF	      | 	OFF
			    ------------------+------------------
  3. On ( default )		ON	      | 	ON
				OFF	      | 	ON

-V1.01 ( 1998/2/24 ) ===> Status : Under testing

* Fix BTC CDROM DOS driver loading failed
* Fix Quantum 12GB drive detecting error

-V1.02 ( 1998/4/13 )

* Add Celeron micro code support
* Add PIIX4E support
* Auto disable unused clock default to enabled
* "Resume by ring" is changed to "Power up by ring/LAN"
* "Resume by Alarm" is changed to "Power up by Alarm"
* Change "Disable" to "Disabled" for Doze, Standby, Suspend Mode and HDD Power
  Down
* MA Wait State Default To Slow to using Fujitsu SDRAM
* Re-sysnc Award BIOS

-V1.03

* Enable spread spectrum to reduce EMI
* Fix game G-NODE can not suspend under DOS
* Fix time to suspend inaccurate
* Change SYMBIOS SCSI BIOS to ver. 4.11.00
* Add Mendocino support ( with 128k L2 cache Celeron )
  BIOS Display difference :
  Celeron 300MHz without L2 Cache --> CELEROM(TM)-MMX at 300MHz
  Celerom 300MHz 128K L2 Cache	  --> CELEROM(TM)-MMX at 300A MHz
  Celerom 333MHz 128K L2 Cache	  --> CELEROM(TM)-MMX at 333MHz
* Add Trend-AntiVirus support
* Change VGA Active Monitor to be disable ( Power management feature )
* Change Delayed Transaction Item default to "Enabled"
  Tekram SCSI CARD+TREND Boot AntiVirus Enabled+Boot from SCSI or Floppy
  ==> System Hang. Because Tekram BIOS will get error 21h port value.
  ==> Workaround for this condition:
	(1) Enable Delayed Transaction
     or (2) Disable Trend Boot AntiVirus detection

  Note : Tekram SCSI BIOS are planned to remove or modify OS/2 patch for
	 interrupt mask operation to avoid this problem.

-V1.04

* Add support for Socket 370 Processor.
  ( Slot1 adapter board for socket 370 is required )

-V1.05

* Fixed the current date shown error (in running NSTL 2000.exe program), when