MANUAIS DE MOTHERBOARDS JBOND |
PCI500C-E
1. CPU Jumper Settings
FOR <MX8325(U9) model>
| Intel
w/o MMX technology |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| 75MHz | NC | NC | NC | NC | ON | ON | 1-2 |
| 90MHz | NC | NC | NC | ON | NC | ON | 2-3 |
| 100MHz | NC | NC | NC | ON | ON | ON | 2-3 |
| 120MHz | NC | ON | NC | ON | NC | ON | 2-3 |
| 133MHz | NC | ON | NC | ON | ON | ON | 2-3 |
| 150MHz | NC | ON | ON | ON | NC | ON | 2-3 |
| 166MHz | NC | ON | ON | ON | ON | ON | 2-3 |
| 180MHz | NC | NC | ON | ON | NC | ON | 2-3 |
| 200MHz | NC | NC | ON | ON | ON | ON | 2-3 |
| AMD
K5 |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| K5-PR75 | NC | NC | NC | NC | ON | ON | 1-2 |
| K5-PR90 | NC | NC | NC | ON | NC | ON | 2-3 |
| K5-PR100 | NC | NC | NC | ON | ON | ON | 2-3 |
| K5-PR120 | NC | ON | NC | ON | NC | ON | 2-3 |
| K5-PR133 | NC | ON | NC | ON | ON | ON | 2-3 |
| K5-PR166 | NC | ON | ON | ON | ON | ON | 2-3 |
| Cyrix
/ IBM
6x86 |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| PR120+GP(50x2) | NC | NC | NC | NC | ON | ON | 1-2 |
| PR150+GP(60x2) | NC | NC | NC | ON | NC | ON | 2-3 |
| PR166+GP(66x2) | NC | ON | NC | ON | ON | ON | 2-3 |
FOR <IMI464(U8) model>
| Intel
w/o MMX technology |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| 75MHz | NC | NC | NC | NC | NC | ON | 1-2 |
| 90MHz | NC | NC | NC | ON | NC | ON | 2-3 |
| 100MHz | NC | NC | NC | ON | ON | ON | 2-3 |
| 120MHz | NC | ON | NC | ON | NC | ON | 2-3 |
| 133MHz | NC | ON | NC | ON | ON | ON | 2-3 |
| 150MHz | NC | ON | ON | ON | NC | ON | 2-3 |
| 166MHz | NC | ON | ON | ON | ON | ON | 2-3 |
| 180MHz | NC | NC | ON | ON | NC | ON | 2-3 |
| 200MHz | NC | NC | ON | ON | ON | ON | 2-3 |
| AMD
K5 |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| K5-PR75 | NC | NC | NC | NC | NC | ON | 1-2 |
| K5-PR90 | NC | NC | NC | ON | NC | ON | 2-3 |
| K5-PR100 | NC | NC | NC | ON | ON | ON | 2-3 |
| K5-PR120 | NC | ON | NC | ON | NC | ON | 2-3 |
| K5-PR133 | NC | ON | NC | ON | ON | ON | 2-3 |
| K5-PR166 | NC | ON | ON | ON | ON | ON | 2-3 |
| Cyrix
/ IBM
6x86 |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| PR120+GP(50x2) | NC | NC | NC | NC | NC | ON | 1-2 |
| PR150+GP(60x2) | NC | NC | NC | ON | NC | ON | 2-3 |
| PR166+GP(66x2) | NC | ON | NC | ON | ON | ON | 2-3 |
FOR <IMI484(U8) model>
| Intel
w/o MMX technology |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| 75MHz | NC | NC | NC | ON | NC | NC | 1-2 |
| 90MHz | NC | NC | NC | ON | NC | ON | 2-3 |
| 100MHz | NC | NC | NC | ON | ON | ON | 2-3 |
| 120MHz | NC | ON | NC | ON | NC | ON | 2-3 |
| 133MHz | NC | ON | NC | ON | ON | ON | 2-3 |
| 150MHz | NC | ON | ON | ON | NC | ON | 2-3 |
| 166MHz | NC | ON | ON | ON | ON | ON | 2-3 |
| 180MHz | NC | NC | ON | ON | NC | ON | 2-3 |
| 200MHz | NC | NC | ON | ON | ON | ON | 2-3 |
| AMD
K5 |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| K5-PR75 | NC | NC | NC | ON | NC | NC | 1-2 |
| K5-PR90 | NC | NC | NC | ON | NC | ON | 2-3 |
| K5-PR100 | NC | NC | NC | ON | ON | ON | 2-3 |
| K5-PR120 | NC | ON | NC | ON | NC | ON | 2-3 |
| K5-PR133 | NC | ON | NC | ON | ON | ON | 2-3 |
| K5-PR166 | NC | ON | ON | ON | ON | ON | 2-3 |
| Cyrix
/ IBM
6x86 |
JP1 | JP2 | JP3 | JP7 | JP8 | JP9 | JP10 |
| PR120+GP(50x2) | NC | NC | NC | ON | NC | NC | 1-2 |
| PR150+GP(60x2) | NC | NC | NC | ON | NC | ON | 2-3 |
| PR166+GP(66x2) | NC | ON | NC | ON | ON | ON | 2-3 |
Note:
2. Clear CMOS Data Jumper Settings
| Operating Mode | JP17 |
| Normal Operating (default) | Short 1-2 |
| Clear CMOS Data | Short 2-3 while computer power turn OFF |
3. External Cache Memory Jumper Settings
| Cache Size | Data SRAM | Tag SRAM | JP12 | JP13 | JP14 | JP15 |
| 256K | Eight 32Kx8 | 8Kx8 | ON | ON | NC | NC |
| 512K | Eight 32Kx8 | 8Kx8 | ON | NC | ON | ON |
4. Support SIMM Module List
5. On-board SCSI Jumper Settings
| On-board SCSI | JP21 | JP22 | JP23 |
| Enable | 2-3 | 2-3 | 2-3 |
| Disable | 1-2 | 1-2 | NC |
6. On-board SCSI Terminator Power Source Jumper Settings
| Operating Mode | JP25 |
| System (Default) | ON |
| Peripheral | NC |
7. Support Year 2000 Compliance
8. Support LS-120 Zip Driver Boot Function
6. Support SCSI/CD-ROM Function