MANUAIS DE MOTHERBOARDS BIOTEQ |
MB-8600TTC
JP2 CMOS function select
Note : Please follow the procedure as below to clear BIOS password if
your password is lost or forgotten.
Power off -> JP2 closed -> power on ->
after memory count finished power off
JP2 open -> power on -> reset your desired password.
JP3 flash ROM type voltage select
1-2 closed: +12V type flash memory used
2-3 closed : +5V type flash memory used
open : EPROM used
JP5 CPU clock
50MHz : 1-2 closed & 3-4 closed
60MHz : 1-2 closed & 3-4 open
66MHz : 1-2 open & 3-4 closed
JP6, JP7, JP8 multiplier of clock
| multiplier | JP6 | JP7 | JP8 |
| 2 | closed | closed | closed |
| 2.5 | closed | closed | open |
| 3 | closed | open | closed |
| 3.5 | closed | open | open |
| CPU speed | JP5(1-2) | JP5(3-4) | JP6 | JP7 | JP8 |
| 133MHz | open | closed | closed | closed | closed |
| 150MHz | closed | open | closed | closed | open |
| 166MHZ | open | closed | closed | closed | open |
| 180MHz | closed | open | closed | open | closed |
| 200MHz | open | closed | closed | open | closed |
| 233MHz | open | closed | closed | open | open |
JP10 CPU voltage select
Open : none VID (2.9V) / VID (auto)
Closed : none VID (3.1V)
JP11 fan power connector
pin 1 : +12V
pin 2 : GND
J12 case connector block
| pin no. |
assignment | function` | pin no. |
assignment | function |
| 1 | speaker | speaker connector |
14 | NC | |
| 2 | NC | 15 | NC | ||
| 3 | ground | 16 | NC | ||
| 4 | VCC | 17 | green control | green switch | |
| 5 | power LED (+) | power LED & keylock |
18 | ground | green switch |
| 6 | NC | 19 | NC | ||
| 7 | ground | 20 | HDD LED (-) | HDD LED | |
| 8 | key lock | 21 | HDD LED (+) | HDD LED | |
| 9 | ground | 22 | NC | ||
| 10 | turbo LED (-) | turbo LED | 23 | NC | |
| 11 | turbo LED (+) | turbo LED | 24 | NC | |
| 12 | reset control | reset | 25 | VCC | VCC |
| 13 | ground | reset | 26 | ground | ground |