| HAWK Main B/D CMOS SETUP | ||||
| 부팅 시 DEL KEY 누름 | ||||
| 1단계 | 2단계 | 3단계 | Default | 선택 옵션 |
| Setup | Standard | Date/Time | 날자, 시간 설정 | |
| Floppy A | Not / 360K 5.¼/ 1.2M 5.¼ / | |||
| Floppy B | 720KB ½ / 1.44M ½ / 2.88M ½ | |||
| Master Disk | Not / 1~45 / User / ESDI / SCSI | |||
| Slave Disk | ||||
| Advanced | Quick Boot | On | On, Off | |
| Typematic Rate(Chars/Sec) | 30 | Disabled, 15, 20, 30 | ||
| System Keyboard | Present | Absent, Present | ||
| Primary Display | VGA/EGA | Absent, VGA/EGA, CGA | ||
| PS/2 Mouse Support | Enable | Disabled, Enabled | ||
| System Boot Up Num Lock | On | On, Off | ||
| OS/2 Compatible Mode | Disabled | Disabled, Enabled | ||
| Floppy Drive Swapping | Disabled | Disabled, Enabled | ||
| System Boot Up Sequence | A:, C: | A:, C: C:, A: | ||
| Password Checking | Always | Setup, Always | ||
| Cache Memory | Both | Disabled, Internal, Both | ||
| Video Shadow C000, 32K | Disabled | Disabled, Enabled | ||
| Adapter Shadow(C800,CC00.... | Disabled | Disabled, Enabled | ||
| PCI VGA Palette Snooping | Disabled | Disabled, Enabled | ||
| 1st,2nd,3rd Available IRQ for PCI/PnP | Disabled | IRQ5/IRQ9/IRQ10/IRQ11 | ||
| Adv HDD | IDE Pri. Master HDD LBA Mode | Enabled | Disabled, Enabled | |
| IDE Pri. Master HDD Block xfer | Enabled | Disabled, Enabled | ||
| IDE Pri. Master HDD 32bit xfer | Enabled | Disabled, Enabled | ||
| IDE Pri. Slave HDD LBA Mode | Enabled | Disabled, Enabled | ||
| IDE Pri. Slave HDD Block xfer | Enabled | Disabled, Enabled | ||
| IDE Pri. Slave HDD 32bit xfer | Enabled | Disabled, Enabled | ||
| Number of HDDs in 2nd Connector | None | None/HDD(+CD)/IDE CD/2HDDs | ||
| IDE Sec. Master HDD LBA Mode | Enabled | Disabled, Enabled | ||
| IDE Sec. Master HDD Block xfer | Enabled | Disabled, Enabled | ||
| IDE Sec. Master HDD 32bit xfer | Enabled | Disabled, Enabled | ||
| IDE Sec. Slave HDD LBA Mode | Enabled | Disabled, Enabled | ||
| IDE Sec. Slave HDD Block xfer | Enabled | Disabled, Enabled | ||
| IDE Sec. Slave HDD 32bit xfer | Enabled | Disabled, Enabled | ||
| Power Mgmt | Advanced Power Management | Enabled | Disabled, Enabled | |
| Full-on to Standby Timeout Value | 10 Min | 기본10분(+/-로 조정 가능) | ||
| Standby to Suspend Timeout Value | 30 Min | 기본30분(+/-로 조정 가능) | ||
| IDE Drive Power Down in | Enabled | Disabled, Enabled | ||
| VESA Video Power Down in | Standby | Standby, Suspend, Off | ||
| Peripheral | Programming Mode | Auto | Auto, Manual | |
| OnBoard FDC | Enabled | Disabled, Enabled | ||
| Serial Port 1 | 3F8H | Disabled, 3F8H, 3E8H | ||
| Serial Port 2 | 2F8H | Disabled, 2F8H, 2F8H | ||
| Parallel Port | 378H | Disabled, 3BCH,378H, 278H | ||
| OnBoard PCI IDE Controller | Enabled | Disabled, Enabled | ||
| Parallel Port Mode | Normal | Normal, Bi-Dir, EPP, ECP | ||
| Parallel Port DMA Channel | 1 | 1, 3 | ||
| Utility | DetectMaster | Primary IDE 커넥터에 연결된 하드 디스크 드라이브 용량을 자동으로 감지 함(Secondary IDE 커넥터에 연결된 하드는 설정 없이 자동 인식) | ||
| DetectSlave | Primary IDE 커넥터에 연결된 하드 디스크 드라이브 용량을 자동으로 감지 함(Secondary IDE 커넥터에 연결된 하드는 설정 없이 자동 인식) | |||
| Color Set | Sky, Army, Pastel, LCD | 셋업 화면 색깔 선택 | ||
| Security | Password | 영 숫자 6자리까지 입력 가능 | ||
| Default | Original | 셋업 변경 전의 단계로 수정 함 | ||
| Optimal | 최적 환경으로 자동 설정 기능(Standard, Utility, Password는 변경 안됨) | |||