BRISTOL Main B/D CMOS SETUP
부팅 시 DEL KEY 누름
1단계 2단계 3단계 선택 옵션

Setup

Standard Date/Time 날자, 시간 설정
Floppy A Not / 360K 5.¼/ 1.2M 5.¼ /
Floppy B 720KB ½ / 1.44M ½ / 2.88M ½
Master Disk Not / 1~46 / User / ESDI / SCSI
Slave Disk  
Advanced Quick Boot :On On, Off
Typematic Rate(Chars/Sec) :30 Disabled, 15, 20, 30
System Keyboard :Present Absent, Present
Primary Display  :VGA/EGA Absent, VGA/EGA, CGA
PS/2 Mouse Support :Enable Disabled, Enabled
System Boot Up Num Lock :On On, Off
Floppy Drive Swapping :Disabled Disabled, Enabled
System Boot Up Sequence :A:, C: A:, C:   C:, A:
External Cache :Enable Disabled, Enabled
Internal Cache :Enable Disabled, Enabled
Password Checking :Always Setup, , Disabled
Video Shadow C000, 32K :Disabled Disabled, Enabled
Shadow(C800,CC00,D000...), 16K :Disabled Disabled, Enabled
Adv HDD IDE Pri. Master HDD Block xfer :Enabled Disabled, Enabled 
IDE Pri. Master HDD LBA Mode :Enabled Disabled, Enabled
IDE Pri. Master HDD 32bit xfer :Enabled Disabled, Enabled
IDE Pri. Slave HDD Block xfer :Enabled Disabled, Enabled
IDE Pri. Slave HDD LBA Mode :Enabled Disabled, Enabled
IDE Pri. Slave HDD 32bit xfer :Enabled Disabled, Enabled
Number of HDDs in 2nd Connector :None None/HDD(+CD)/IDE CD/2HDDs
IDE Sec. Master HDD Block xfer :Enabled Disabled, Enabled
IDE Sec. Master HDD LBA Mode :Enabled Disabled, Enabled
IDE Sec. Master HDD 32bit xfer :Enabled Disabled, Enabled
IDE Sec. Slave HDD Block xfer :Enabled Disabled, Enabled
IDE Sec. Slave HDD LBA Mode :Enabled Disabled, Enabled
IDE Sec. Slave HDD 32bit xfer Enabled Disabled, Enabled
Power Mgmt Advanced Power Management :Enabled Disabled, Enabled
IDE Drive Power Down in :Enabled Disabled, Enabled
VESA Video Power Down in :Standby Disabled, Standby, Suspend, Off
Monitor VGA Activity :Disabled Disabled, Enabled
Timeout Value :15 9, 15, 21, 27, 34, 40 ....99
Peripheral Programming Mode :Auto Auto, Manual
OnBoard FDC :Enabled Disabled, Enabled
Serial Port 1 :3F8H Disabled, 3F8H, 3E8H
Serial Port 2 :2F8H Disabled, 2F8H, 2F8H
Parallel Port :378H Disabled, 3BCH,378H, 278H
OnBoard PCI Board :Enabled Disabled, Enabled
Parallel Port Mode :Normal Normal, Extended
Parallel Extended Mode BI-dir Bi-dir, EPP, ECP, EPP&ECP

Utility

DetectMaster Primary IDE 커넥터에 연결된 하드 디스크 드라이브 용량을 자동으로 감
DetectSlave 지 함(Secondary IDE 커넥터에 연결된 하드는 설정 없이 자동 인식)
Color Set Sky, Army, Pastel, LCD 셋업 화면 색깔 선택
Security Password 영 숫자 6자리까지 입력 가능
Anti-Virus 바이러스의 보호 기능, 하드의 부트 섹터에 Write 방지 기능
Default Original 셋업 변경 전의 단계로 수정 함
Optimal 최적 환경으로 자동 설정 기능(Standard, Utility, Password는 변경 안됨)
Fail-safe 가장 안정된 값을 자동 설정