| Pin | Signal Name | Pin | Signal Name |
|---|---|---|---|
| 1 | Ground | 35 | Terminator power |
| 2 | Data 12 | 36 | Terminator power |
| 3 | Ground | 37 | Reserved |
| 4 | Data 13 | 38 | Reserved |
| 5 | Ground | 39 | Ground |
| 6 | Data 14 | 40 | Ground |
| 7 | Ground | 41 | Ground |
| 8 | Data 15 | 42 | -Attention |
| 9 | Ground | 43 | Ground |
| 10 | Data P1 | 44 | Ground |
| 11 | Ground | 45 | Ground |
| 12 | Data 0 | 46 | -Busy |
| 13 | Ground | 47 | Ground |
| 14 | Data 1 | 48 | -Acknowledge |
| 15 | Ground | 49 | Ground |
| 16 | Data 2 | 50 | -Reset |
| 17 | Ground | 51 | Ground |
| 18 | Data 3 | 52 | -Message |
| 19 | Ground | 53 | Ground |
| 20 | Data 4 | 54 | -Select |
| 21 | Ground | 55 | Ground |
| 22 | Data 5 | 56 | -Control/Data |
| 23 | Ground | 57 | Ground |
| 24 | Data 6 | 58 | -Request |
| 25 | Ground | 59 | Ground |
| 26 | Data 7 | 60 | -Input/Output |
| 27 | Ground | 61 | Ground |
| 28 | Data P | 62 | Data 8 |
| 29 | Ground | 63 | Ground |
| 30 | Ground | 64 | Data 9 |
| 31 | Ground | 65 | Ground |
| 32 | Ground | 66 | Data 10 |
| 33 | Terminator Power | 67 | Ground |
| 34 | Terminator Power | 68 | Data 11 |