Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

PC Doctor Diagnostics Error Codes and Messages



PC Doctor Diagnostics Error Codes and Messages

The following table does not include userinitiated aborts, which display the error type 195.

Error Code 0-199

Error Code Test(s) Message
0-199 Y2K Year 2000 issue detected


FRU/Action in Sequence:


Error Code 1-1 to 1-260

Error Code Test(s) Message
1-1 SMBUS No SMBUS detected (if iFailNoSmbus=1)
1-34 DMA DMA transfer buffer allocate
1-198 SMBUS No SMBUS detected (if iFailNoSmbus=0)
1-254 DMA DMA transfer
1-255 DMA DMA page register
1-256 DMA DMA register
1-260 IRQ IRQ controller


FRU/Action in Sequence:


Error Code 1-286 to 1-300

Error Code Test(s) Message
1-286 Timer Timer 0
BIOS timer
1-287 Timer Timer 1
RAM refresh
1-288 Timer Timer 2
1-292 CMOS RAM Pattern test
1-298 RTC Time update
1-299 RTC Periodic interrupt
1-300 RTC Alarm interrupt


FRU/Action in Sequence:


Error Code 5-16 to 15-36

Error Code Test(s) Message
5-16 Video Memory pattern failed
5-24 Video Video page test failed
5-26 Video Register failed
5-199 Video Could not initialize mode 13H for
register test.
11-2 COM Timeout sending
11-13 COM LCR/MCR fail
11-14 COM Internal loopback
11-15 COM External loopback
11-40 COM No interrupt detected
11-197 COM No FIFO part (can't run FIFO test)
IR mode enabled (can't run serial test)
No external loopback adapter (if prompt
times out)
11-198 COM Aborted
11-286 COM Baudrate register
11-290 COM DLAB
14-15 LPT External loopback fail
14-40 LPT No interrupt
14-196 LPT Test aborted (too many failures)
14-197 LPT No loopback (prompt timed out)
14-250 LPT Data register
15-1 USB Not detected
15-36 USB Register failed


FRU/Action in Sequence:


Error Code 18-1 to 18-27

Error Code Test(s) Message
18-1 PCMCIA No PCMCIA detected
18-5 PCMCIA Incorrect PCMCIA version
18-9 PCMCIA Incorrect number of sockets
18-24 PCMCIA Index register failed
18-27 PCMCIA Socket configuration read error


FRU/Action in Sequence:


Error Code 20-1 to 71-41

Error Code Test(s) Message
20-1 PCI No PCI detected
20-5 PCI Incorrect PCI BIOS version
20-27 PCI Problem reading PCI configuration
20-196 PCI To many PCI errors
25-14 IDE Controller data loop
25-32 IDE Inquiry data change between reads
25-195 IDE User abort
25-198 IDE No drive parameters readable
Testing parameters out of range
25-250 IDE POST/BIST
25-260 IDE Read/verify
25-262 IDE Seek error
71-1 SB - PNPISA sound card detected,
but not enabled
- PCI sound card detected,
but not enabled
- Sound card not detected
71-11 SB DSP data loopback failed
71-40 SB IRQ test failed
71-41 SB DMA test failed


FRU/Action in Sequence:


Error Code 75-1

Error Code Test(s) Message
20-1 PCI No PCI detected
75-1 ACCHARGER AC Charger not supported


FRU/Action in Sequence:


Error Code 89-250 to 89-294

Error Code Test(s) Message
89-250 CPU Math coprocessor
89-266 CPU Registers
MMX™
89-278 CPU Arithmetics
89-282 CPU Logical ops
89-286 CPU String ops
89-294 CPU Exceptions


FRU/Action in Sequence:


Error Code 170-1 to 175-198

Error Code Test(s) Message
170-1 LM80/LM81 Chip not detected (iFailNoLm80=1)
170-27 LM80/LM81 All interrupts masked
170-198 LM80/LM81 Chip not detected (iFailNoLm80=0)
170-250 LM80/LM81 Interrupt condition detected
175-1 LM75/
Max1617
FAN
Chip not detected (iFailNoLm80=1)
Fan test not supported
No fan detected
175-198 LM75/
Max1617
Chip not detected (iFailNoLm80=0)


FRU/Action in Sequence:


Error Code 175-199

Error Code Test(s) Message
175-199 FAN Fan test failed


FRU/Action in Sequence:


Error Code 175-250 to 185-262

Error Code Test(s) Message
175-250 LM75/
Max1617
Interrupt condition detected
185-1 RFID/
ALERTPACK
Asset ID not supported
SMBUS not detected (if not required)
AlertPack not supported
AlertPack not detected (if not required)
185-2 ALERTPACK Transmission timeout
185-5 ALERTPACK Invalid revision
185-9 RFID/
ALERTPACK
SMBUS not detected (if required)
AlertPack not detected (if required)
185-16 ALERTPACK Pattern test
185-262 RFID/
ALERTPACK
Problem reading EEPROM
Bad header checksum
Bad area checksum
Problem detecting antenna
No antenna detected


FRU/Action in Sequence:


Error Code 201-1 to 201-198

Error Code Test(s) Message
201-1 DIMM No SMBus detected (iFailNoSmbus=1)
No DIMMs detected (iFailNoSmbus=1)
201-13 DIMM EEPROM write protect failed
(iFailEpWr=1)
201-25 DIMM Bad EEPROM checksum
201-198 DIMM No SMBus detected (iFailNoSmbus=0)


FRU/Action in Sequence:


Error Code 202-1 to 202-18

Error Code Test(s) Message
202-1 CACHE CPU not in correct mode for test
202-3 CACHE NMI detected during cache test
202-18 CACHE Cache failed random pattern test


FRU/Action in Sequence:


Error Code 206-16 to 206-290

Error Code Test(s) Message
206-16 FD Sector pattern test failed
206-27 FD Read failure
(not able to detect disk size)
206-198 FD Not able to detect disk size parameters
206-262 FD Read, write or verify failure
206-290 FD Seek failed


FRU/Action in Sequence:


Error Code 215-1 to 215-254

Error Code Test(s) Message
215-1 CDROM No drive or MSCDEX driver detected
215-196 CDROM Too many errors
215-254 CDROM Sector read failed


FRU/Action in Sequence:


Error Code 217-14 to 217-262

Error Code Test(s) Message
217-14 HD Controller data loop
217-32 HD Inquiry data change between reads
217-195 HD User abort
217-198 HD No drive parameters readable
Testing parameters out of range
217-250 HD POST/BIST
217-260 HD Read/verify
217-262 HD Seek error


FRU/Action in Sequence:


Error Code 301-250 to 301-266

Error Code Test(s) Message
301-250 KBD Interrupt
301-254 KBD POST
301-258 KBD Interface


FRU/Action in Sequence:


Error Code 304-1 to 304-199

Error Code Test(s) Message
304-1 BATTERY No battery installed
No battery detected
304-199 BATTERY General battery failure


FRU/Action in Sequence:


Error Code 415-1 to 415-250

Error Code Test(s) Message
415-1 MODEM PNPISA modem detected but not enabled
PCI modem detected but not enabled
Modem not detected
415-250 COM/Modem Modem ATZ
No dial tone detected


FRU/Action in Sequence: