Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric Error Codes



  Numeric Error Codes

The following is a list of the message that the BIOS can display.
Most of them occur during POST. Some of them display information about a hardware device, e.g., the amount of memory installed. Others may indicate a problem with a device, such as the way it has been configured. Following the list are explanations of the messages and remedies for reported problems.

If the system fails after you make changes in the Setup menus, reset the computer, enter Setup and install Setup defaults or correct the error.

Symptom/Error    FRU/Action in Sequence
  
0200 1. Reseat hard disk drive.
Failure Fixed Disk 2. Load Setup Defaults in BIOS Setup Utility.
  3. Hard disk drive
  4. System/planar board
  
0211    Go to 'Keyboard and Auxiliary Input Device Checkout'.
Stuck Key
0211    Go to 'Keyboard and Auxiliary Input Device Checkout'.
Keyboard error
0212    Go to 'Keyboard and Auxiliary Input Device Checkout'.
Keyboard Controller
Failed
0213    Unlock external keyboard.
Keyboard locked -
Unlock key switch
0220    Load Setup Defaults in BIOS Setup Utility.
Monitor type does
not match CMOS
- Run Setup
0230 1. BIOS ROM
Shadow RAM Failed at 2. Planar board
offset:nnnn
0231 1. DIMM
System RAM Failed at 2. Planar board
offset:nnnn
0232 1. DIMM
Extended RAM Failed 2. System/planar board
at offset:nnnn
0250    Replace backup battery (RTC) and run BIOS Setup Utility
System battery is    to reconfigure the system time, then reboot the system.
dead -
Replace and run SETUP
0251 1. Backup battery (RTC)
System CMOS checksum 2. Run BIOS Setup Utility to reconfigure the system,
bad - Default     then reboot the system.
configuration used
0260 1. Backtup battery (RTC)
System timer error 2. Run BIOS Setup Utility to reconfigure the system,
      then reboot the system.
  3. System/planar board
  
0270 1. Backtup battery (RTC)
Real time clock error 2. Run BIOS Setup Utility to reconfigure the system,
      then reboot the system.
  3. System/planar board
  
0280 1. Load Setup Defaults in the BIOS Setup Utility.
Previous boot incomplete - 2. Backup battery (RTC)
Default configuration used 3. System/planar board
  
0281 1. Load Setup Defaults in the BIOS Setup Utility.
Memory size found by 2. DIMM
POST differed from CMOS 3. System/planar board
  
02B0 1. Check that the drive is defined with the proper
Diskette drive A error     diskette type in BIOS Setup Utility.
  2. Go to 'Diskette Drive Checkout'.
  
02B2 1. Check that the drive is defined with the proper
Incorrect Drive A type     diskette type in BIOS Setup Utility.
- run SETUP 2. Go to 'Diskette Drive Checkout'.
  
02D0 1. CPU card
System cache error 2. System/planar board
- Cache disabled
02F0 1. CPU card
CPU ID: 2. System/planar board
  
02F5 1. DIMM
DMA Test Failed 2. CPU card
  3. System/planar board
  
02F6 1. DIMM
Software NMI Failed 2. CPU card
  3. System/planar board
  
02F7 1. DIMM
Fail-Safe Timer NMI 2. CPU card
Failed 3. System/planar board


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.