Numeric Error Codes (2625 365X, XD - 2635 380-385)



  Numeric Error Codes

Symptom / Error    FRU / Action in Sequence
  
10X 1. System Board
101 Interrupt failure.
102 Timer failure.
103 Timer interrupt failure.
104 Protected mode failure.
105 Last 8042 command not accepted.
107 NMI test failure.
108 Timer bus test failure.
109 Low meg-chip select test.
110 1. Go to 'Memory Checkout'
(Planar parity.) 2. DIMM
  3. The computer is attached to a Port Replicator.
  4. System Board
  
111 1. Go to 'Memory Checkout'
(I/O parity.) 2. Port Replicator
  3. System Board
  
158 1. Set an HDP for the hard disk drive.
(HDP was not set even though
the supervisor password is set.)
159 1. Set a correct HDP for the hard disk drive.
(HDP is not set the same
as the supervisor password.)
161 1. Go to 'Checking the Backup Battery'.
(Dead battery.) 2. Backup Battery
  3. System Board
  
163 1. Set Time and Date.
(Time and Date were not set.) 2. Backup Battery
  3. System Board
  
173 1. Select OK in the error screen,
(Configuration data was lost.)     then set the time and date
  2. Backup Battery
  3. System Board
  
174 1. Check Device Configuration.
(Configuration error: Perform 2. System Board
'Checking the Installed Devices List' 3. Diskette Drive Assembly
before changing any FRUs.) 4. Hard Disk Drive Assembly
  
175, 177, 178 1. System Board
175 EEPROM CRC #1 error.
177 Supervisor password check sum error.
178 EEPROM is not functional.
183 1. Have the user examine the password.
(Incorrect password entered
at the supervisor
password prompt.)
184 1. Reset the POP (power-on password) in Easy-Setup.
(POP check sum error.)
185 1. Reset the startup sequence
(The startup sequence is not     in Easy-Setup.
valid. Suspect that power was
off when the startup sequence
was being updated.)
186 1. System Board
  
188 1. Set the system identification
(EEPROM CRC #2 error.)     using the ThinkPad Hardware Maint.
      Diskette.
  
190 1. Go to 'Checking the Battery Pack'
(Depleted battery pack was
installed when the power was on.)
191XX 1. System Board
(PM initialization error.) 2. CPU card
  
195 1. Check if the configuration was changed.
(The configuration read     For example, check if the hard disk drive
from the hibernation area     is from another computer
does not match the     Also, when a DIMM card has been installed,
the actual configuration.)     unsecured DIMM latches can result in this error.
      Make sure the DIMM is securely seated and fully
      latched into place.
  
196 1. Run the hard disk drive test.
(Read error occurred in the 2. Hard Disk Drive
hibernation area of the HDD.)
199XX 1. System Board
(Resume error.)
1XX 1. System Board
  
2XX 1. Go to 'Memory Checkout'.
201 Memory data error. 2. DIMM
202 Memory line error 00-15. 3. System Board
203 Memory line error 16-23.
205 Memory test failure on on-board memory.
221 ROM to RAM remap error.
301, 303, 304, 305, 3XX 1. Go to 'Keyboard/Aux. Input Device Checkout'
(301: Keyboard error.) 2. Keyboard
  3. External Numeric Keypad
  4. External Keyboard
  5. Keyboard/Mouse Cable
  6. Keyboard Card
  7. System Board
  
601, 6XX 1. Go to 'Diskette Drive Test'.
(601: Diskette drive 2. Diskette Drive Assembly
or controller error.) 3. Diskette
  4. System Board
  
602 1. Go to 'Diskette Drive Test'.
(Diskette read error.) 2. Diskette
  3. Diskette Drive Assembly
  
604 1. Go to 'Diskette Drive Test'.
(Unacceptable ID was read 2. Diskette Drive Assembly
from the diskette drive.) 3. System Board
  
11XX 1. Serial Device
1101: Serial_A test failure. 2. Communication Cable
  3. System Board
  
12XX 1. System Board
1201: Serial_B test failure.
17XX 1. Hard Disk Drive
1701 Hard disk controller failure. 2. System Board
1780, 1790 Hard disk 0 error.
1781, 1791 Hard disk 1 error.
24XX 1. System Board
(2401: System board video error.)
808X 1. Reseat the PCMCIA Connector.
8081 PCMCIA presence 2. PCMCIA Slot Assembly
test failure. 3. PCMCIA Device
(PCMCIA revision number 4. System Board
also checked.)
8082 PCMCIA register
test failure.
860X 1. External Mouse
(Pointing device error 2. External Keyboard
when TrackPoint III is 3. System Board
disabled.)
8601 System bus error-8042
mouse interface.
8602 External mouse error.
8603 System bus error or mouse error.
861X 1. Reseat the keyboard connector.
(Pointing device error 2. Reseat the keyboard TrackPoint III
when TrackPoint III is enabled.)     cable on the keyboard card.
8611 System bus error-I/F     See '1070 Keyboard Unit'.
between 8042 and IPDC. 3. Keyboard
8612 TrackPoint error. 4. External Mouse
8613 System board or 5. 4System Board
TrackPoint error.
I9990301 1. Reseat the boot device.
I9990302 2. Check the startup sequence for
I9990305     the correct boot device.
I9990301 Hard disk error. 3. Check that the operating system has
I9990302 Invalid hard disk     no failure and is installed correctly.
boot record.
I9990305 No bootable device.
I9990303 1. System Board
(Bank 2 flash ROM check sum error.)
Other codes not listed above 1. Go to 'Undetermined Problems'.