Numeric Error Codes (2640-560 - 60x, 70x)



Numeric Error Codes

Symptom/Error    FRU/Action
  
10X 1. System Board
101 Interrupt failure
102 Timer failure
103 Timer interrupt failure
104 Protected mode failure
105 Last 8042 command-
-not accepted
107 NMI test failure
108 Timer bus test failure
109 Low meg-chip select test
110 1. Go to 'Memory Checkout'
  2. DIMM Card
  3. The computer is attached to the expansion unit
  4. System Board
  
111 1. Go to 'Memory Checkout'
  2. System Board
  
158 1. Set the password for hard disk drive
(Hard disk password was not set
even thought the supervisor
password is set.)
159 1. Set the correct password for hard disk drive
(Hard disk password is not set
the same as the supervisor
password.)
161 1. Go to 'Checking the Backup Battery'
(Dead battery) 2. Backup Battery
  3. System Board
  
163 1. Reseat the keyboard connector
(Time and Date was not set.)     on the system board
  2. Set Time and Date
  3. System Board
  
173 1. Reseat the keyboard connector
(Configuration data were lost.)     on the system board
  2. Select OK in the error screen,
      then set time and date.
  3. Backup Battery
  4. System Board
  
174 1. Check Device Configuration.
Configuration error (Perform 2. System Board
'Checking the Installed Devices List' 3. Diskette Drive Assembly
before changing any FRUs.) 4. Hard Disk Drive Assembly
  
175, 177, 178 1. System Board
175: EEPROM CRC #1 error
177: Supervisor password
checksum error.
178: EEPROM is not functional
183 1. Have the user examine the password
(Incorrect password entered at
the supervisor password prompt.)
184 1. Reset the POP in Easy-Setup.
(POP check sum error.)
185 1. Reset the startup sequence in Easy-Setup.
(The startup sequence is not
valid. Suspect that power was off
when the startup sequence was
beeing updated.)
186 1. System Board.
  
190 1. Go to 'Checking the Battery Pack'
(A depleted battery pack was
installed when the power was on.)
191XX 1. System Board
(PM initialzation error)
195 1. Check if the configuration
(The configuration read from the     was changed
hibernation area does not match     For example, check if the DIMM card
the actual configuration.)     is added.
  
196 1. Run the hard disk drive test
(Read error occured in the 2. Hard Disk Drive
hibernation area of the HDD.)
1XX 1. System Board
  
2XX 1. Go to 'Memory Checkout'
201 Memory data error 2. DIMM Card
202 Memory line error 00-15 3. System Board
203 Memory line error 16-23
205 Memory test failure on
on-board memory
221 ROM to RAM remap error
301, 303, 304, 305, 3XX 1. Go to 'Keyboard / Auxiliary Input Device Checkout'
(Keyboard error) 2. Keyboard
  3. External Numeric Keypad
  4. External Keyboard
  5. Keyboard/Mouse Cable
  6. System Board
  
601, 6XX 1. Go to 'Diskette Drive Checkout'
(Diskette drive or 2. Diskette Drive Assembly
 
controller error.) 3. Diskette
  4. System Board
  
602 1. Go to 'Diskette Drive Checkout'
(Diskette read error.) 2. Diskette
  3. Diskette Drive Assembly
  
604 1. Go to 'Diskette Drive Checkout'
(Non-acceptable ID was read 2. Diskette Drive Assembly
from the diskette drive.) 3. System Board
  
11XX 1. Serial Device (First)
1101 Serial A test failure 2. Communication Cable
  3. System Board
  
12XX 1. System Board (Infrared)
1101 Serial B test failure
17XX 1. Hard Disk Drive
1701 Hard sisk controller failure 2. System Board
1780, 1790 Hard disk 0 error
1781, 1791 Hard disk 1 error
24XX 1. System Board
2401 System board video error
808X 1. PCMCIA Slot Assembly
8081 PCMCIA presence test failure 2. PCMCIA Device
(PCMCIA revision also checked) 3. System Board
8082 PCMCIA register test failure
860X 1. External Mouse
(Pointing device error when 2. External Keyboard
TrackPoint III is disabled.) 3. System Board
8601 Systembus error-
8042 mouse interface
8602 External mouse error
8603 System bus error or
mouse error
861X 1. Reseat the keyboard cable on
(Pointing device error when     the systemboard.
TrackPoint III is enabled.) 2. Keyboard
8611 System bus error-I/F between 3. External Mouse
8042 and IPDC 4. System Board
8612 TrackPoint error
8613 System board or TrackPoint error.
I9990301 1. Check that the operating system.
I9990302     is installed in the HDD.
I9990305     If not, install the operating system.
I9990301 Hard disk error 2. Reseat the boot device
I9990302 Invalid hard disk boot 3. Check the startup sequence for the correct
record.     boot device.
I9990305 No bootable device 4. Check that the operating system has no
      failure and is installed correctly
  
I9990303 1. System Board
Bank-2 flash ROM checksum error
Other codes not listed above 1. Go to 'Undetermined Problems'