| Symptom/Error | FRU/Action |
|---|---|
| 10X | 1. System Board |
| 110 | 1. Go to 'Memory Checkout' |
| 2. IC DRAM Card or DIMM Card | |
| 3. System Board | |
| 111 | 1. Go to 'Memory Checkout' |
| 2. Expansion Unit/Port Replicator | |
| 3. System Board | |
| 158 | 1. Set a HDP. |
| (HDP was not set even | |
| though the supervisor | |
| password is set.) | |
| 159 | 1. Set a correct HDP. |
| (HDP is not set the same | |
| as the supervisor password.) | |
| 161 | 1. Go to 'Checking the Backup Battery' |
| 2. Backup Battery | |
| 3. System Board | |
| 163 | 1. Set Time and Date. |
| (Time and Date was not set.) | 2. System Board |
| 173 | 1. Select OK in the error screen |
| (Configuration data were lost.) | then set time and date |
| 2. Backup Battery | |
| 3. System Board | |
| 174 | 1. Check Device Configuration. |
| (Perform | 2. System Board |
| 'Checking the Installed Devices List' | 3. Diskette Drive Assembly |
| before changing any FRUs) | 4. Hard Disk Drive Assembly |
| 175, 177, 178 | 1. System Board |
| 183 | 1. Have the user examine the password. |
| (Incorrect password entered | |
| at the supervisor password | |
| prompt.) | |
| 184 | 1. Reset the POP in Easy-Setup. |
| (POP check sum error.) | |
| 185 | 1. Reset the startup sequence |
| (The startup sequence is | in Easy-Setup. |
| not valid. | |
| Suspect that power was off | |
| when the startup sequence | |
| was being updated.) | |
| 186 | 1. System Board |
| 188 | 1. Set the system identification |
| using the ThinkPad 750Ce | |
| hardware maintenance diskette. | |
| 190 | 1. Go to 'Checking the Battery Pack' |
| (Depleted battery pack was | |
| installed when the power was on.) | |
| 191XX | 1. System Board |
| 2. Processor card | |
| 195 | 1. Check if the configuration was changed. |
| (The configuration read | For example, check if the disk drive is |
| from the hibernation area | from another computer |
| does not match the actual | |
| configuration.) | |
| 196 | 1. Run the hard disk drive test. |
| (Read error occurred in the | 2. Hard Disk Drive |
| hibernation area of the HDD.) | |
| 199XX | 1. System Board |
| 1XX | 1. System Board |
| 2XX | 1. Go to 'Memory Checkout' |
| 2. IC DRAM Card, DIMM, or DIMM Adapter | |
| 3. System Board | |
| 301, 303, 304, 305, 3XX | 1. Go to 'Keyboard / Auxiliary Input Device Checkout' |
| 2. Keyboard | |
| 3. Video Card | |
| 4. External Numeric Keypad | |
| 5. External Keyboard | |
| 6. Keyboard/Mouse Cable | |
| 7. System Board | |
| 601, 6XX | 1. Go to 'Diskette Drive Test' |
| 2. Diskette Drive Assembly | |
| 3. Diskette | |
| 4. System Board | |
| 602 | 1. Go to 'Diskette Drive Test' |
| (Diskette read error.) | 2. Diskette |
| 3. Diskette Drive Assembly | |
| 604 | 1. Go to 'Diskette Drive Test' |
| (Non-acceptable ID was read | 2. Diskette Drive Assembly |
| from the diskette drive.) | 3. System Board |
| 11XX | 1. Serial Device (First) |
| 2. Communication Cable | |
| 3. System Board | |
| 12XX | 1. Serial Device (Second) |
| 2. Communication Cable | |
| 3. System Board | |
| 17XX | 1. Hard Disk Drive |
| 2. System Board | |
| 24XX | 1. System Board |
| 2. Video Card | |
| 808X | 1. PCMCIA Slot Assembly |
| 2. PCMCIA Device | |
| 3. System Board | |
| 860X | 1. External Mouse |
| (Pointing device error when | 2. External Keyboard |
| TrackPoint III is disabled.) | 3. System Board |
| 861X | 1. Reseat the keyboard Track Point III |
| (Pointing device error when | cable at the interposer card |
| TrackPoint III is enabled.) | See '1080 Keyboard Unit' |
| 2. Keyboard | |
| 3. External Mouse | |
| 4. Video Card | |
| 5. System Board | |
| I9990301 | 1. Reseat the boot device. |
| I9990302 | 2. Check the startup sequence for the correct |
| I9990305 | boot device. |
| 3. Check that operating system has no failure | |
| or is installed correctly. | |
| I9990303 | 1. System Board |
| Other codes not listed above | 1. Go to 'Undetermined Problems' |
Please see the LEGAL - Trademark notice.