Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric Error Codes



Numeric Error Codes

Symptom/Error    FRU/Action
  
10X 1. System Board
  
110 1. Go to 'Memory Checkout'
  2. IC DRAM Card or DIMM Card
  3. System Board
  
111 1. Go to 'Memory Checkout'
  2. Expansion Unit/Port Replicator
  3. System Board
  
158 1. Set a HDP.
(HDP was not set even
though the supervisor
password is set.)
159 1. Set a correct HDP.
(HDP is not set the same
as the supervisor password.)
161 1. Go to 'Checking the Backup Battery'
  2. Backup Battery
  3. System Board
  
163 1. Set Time and Date.
(Time and Date was not set.) 2. System Board
  
173 1. Select OK in the error screen
(Configuration data were lost.)     then set time and date
  2. Backup Battery
  3. System Board
  
174 1. Check Device Configuration.
(Perform 2. System Board
'Checking the Installed Devices List' 3. Diskette Drive Assembly
before changing any FRUs) 4. Hard Disk Drive Assembly
  
175, 177, 178 1. System Board
  
183 1. Have the user examine the password.
(Incorrect password entered
at the supervisor password
prompt.)
184 1. Reset the POP in Easy-Setup.
(POP check sum error.)
185 1. Reset the startup sequence
(The startup sequence is     in Easy-Setup.
not valid.
Suspect that power was off
when the startup sequence
was being updated.)
186 1. System Board
  
188 1. Set the system identification
      using the ThinkPad 750Ce
      hardware maintenance diskette.
  
190 1. Go to 'Checking the Battery Pack'
(Depleted battery pack was
installed when the power was on.)
191XX 1. System Board
  2. Processor card
  
195 1. Check if the configuration was changed.
(The configuration read     For example, check if the disk drive is
from the hibernation area     from another computer
does not match the actual
configuration.)
196 1. Run the hard disk drive test.
(Read error occurred in the 2. Hard Disk Drive
hibernation area of the HDD.)
199XX 1. System Board
  
1XX 1. System Board
  
2XX 1. Go to 'Memory Checkout'
  2. IC DRAM Card, DIMM, or DIMM Adapter
  3. System Board
  
301, 303, 304, 305, 3XX 1. Go to 'Keyboard / Auxiliary Input Device Checkout'
  2. Keyboard
  3. Video Card
  4. External Numeric Keypad
  5. External Keyboard
  6. Keyboard/Mouse Cable
  7. System Board
  
601, 6XX 1. Go to 'Diskette Drive Test'
  2. Diskette Drive Assembly
  3. Diskette
  4. System Board
  
602 1. Go to 'Diskette Drive Test'
(Diskette read error.) 2. Diskette
  3. Diskette Drive Assembly
  
604 1. Go to 'Diskette Drive Test'
(Non-acceptable ID was read 2. Diskette Drive Assembly
from the diskette drive.) 3. System Board
  
11XX 1. Serial Device (First)
  2. Communication Cable
  3. System Board
  
12XX 1. Serial Device (Second)
  2. Communication Cable
  3. System Board
  
17XX 1. Hard Disk Drive
  2. System Board
  
24XX 1. System Board
  2. Video Card
  
808X 1. PCMCIA Slot Assembly
  2. PCMCIA Device
  3. System Board
  
860X 1. External Mouse
(Pointing device error when 2. External Keyboard
TrackPoint III is disabled.) 3. System Board
  
861X 1. Reseat the keyboard Track Point III
(Pointing device error when     cable at the interposer card
TrackPoint III is enabled.)     See '2080 Keyboard Unit'
  2. Keyboard
  3. External Mouse
  4. Video Card
  5. System Board
  
I9990301 1. Reseat the boot device.
I9990302 2. Check the startup sequence for the correct
I9990305     boot device.
  3. Check that operating system has no failure
      or is installed correctly.
  
I9990303 1. System Board
  
Other codes not listed above 1. Go to 'Undetermined Problems'


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.