Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric Error Codes



Numeric Error Codes

Symptom/Error    FRU/Action
  
10X 1. System Board
  
110 1. Go to 'Memory Checkout'
  2. IC DRAM Card
  3. System Board
  
111 1. Go to 'Memory Checkout'
  2. System Board
  
161 1. Go to 'Checking the Backup Battery'
  2. Backup Battery
  3. System Board
  
163 1. Set Time and Date.
(Time and Date was not set.) 2. System Board
  
173 1. Select OK in the error screen,
(Configuration data were lost.)     then set time and date.
  2. Backup Battery
  3. System Board
  
174 1. Check Device Configuration.
(Perform 2. System Board
'Checking the Installed Devices List' 3. Diskette Drive Assembly
before changing any FRUs.) 4. Hard Disk Drive Assembly
  
184 1. Reset the POP in Easy-Setup.
(POP check sum error.)
190 1. Go to 'Checking the Battery Pack'
(A depleted battery pack was
installed when the power was on.)
191XX 1. System Board
  
199XX 1. System Board
  
1XX 1. System Board
  
2XX 1. Go to 'Memory Checkout'
  2. IC DRAM Card
  3. System Board
  
301, 303, 304, 305, 3XX 1. Go to 'Keyboard / Auxiliary Input Device Checkout'
  2. Keyboard
  3. External Numeric Keypad
  4. External Keyboard
  5. Keyboard/Mouse Cable
  6. System Board
  
601, 6XX 1. Go to 'Diskette Drive Test'
  2. Diskette Drive Assembly
  3. Diskette
  4. System Board
  
602 1. Go to 'Diskette Drive Test'
(Diskette read error.) 2. Diskette
  3. Diskette Drive Assembly
  
604 1. Go to 'Diskette Drive Test'
(Non-acceptable ID was read 2. Diskette Drive Assembly
from the diskette drive.) 3. System Board
  
11XX 1. Serial Device (First)
  2. Communication Cable
  3. System Board
  
12XX 1. Serial Device (Second)
  2. Communication Cable
  3. System Board
  
17XX 1. Hard Disk Drive
  2. System Board
  
24XX 1. System Board
  
808X 1. PCMCIA Slot Assembly
  2. PCMCIA Device
  3. System Board
  
860X 1. External Mouse
(Pointing device error when 2. External Keyboard
TrackPoint II or III is disabled.) 3. System Board
  
861X 1. Reseat the keyboard TrackPoint
(Pointing device error when     II or III cable.
TrackPoint II or III is enabled.)     (See '1080 Keyboard Unit')
  2. Keyboard
  3. External Mouse
  4. System Board
  
I9990301 1. Reseat the boot device.
I9990302 2. Check the startup sequence
I9990305     for the correct boot device.
  3. Check that the operating system has no
      failures, and is installed correctly.
  
I9990303 1. System Board
  
Other codes not listed above 1. Go to 'Undetermined Problems'


More INFORMATION / HELP is available at the  IBM-HelpCenter